My ge window air conditioner won t turn on using either the touch pad or the remote control.
Ge ac window unit won t turn on.
At ge appliances our goal is to ensure your satisfaction while offering the highest levels of professional service at affordable and competitive rates.
Schedule service online update a service appointment or check pricing.
Make sure the.
When i reset it the light next to the delay comes on an 8 displays then turns into a minus sign then it shuts off.
It is not the power source.
By providing its own high voltage plug.
If the fuse burns out again provide a dedicated 120 volt plug for the unit.
Check to see if it has blown using a multi meter if necessary.
Check to ensure that the power supply to your unit is good then unplug the air conditioner and remove the cabinet cover.
I already checked that.
When power is restored wait 3 minutes to restart the air conditioner to prevent tripping of the com pressor overload.
If the air conditioner draws power from a circuit shared by other appliances it can t draw required power supply and will blow the fuse repeatedly.
Newer model units often have a built in circuit breaker in the supply cord so check to see if that has tripped.
Your ac won t turn on until you clean out your drains and get the float switch back into the down position.
Answered in 2 minutes by.
Make sure the air conditioner plug is pushed completely into the outlet.
Once the fuse has been replaced check the machine by running it again.
Check and adjust if necessary the air directional louvers upward to promote improved airflow.
Ask your own appliance question.
Use of this option may cause your utility bill to increase.
If your window air conditioner won t turn on it may be that it is not getting any power.
It just suddenly won t turn on.
Window ac units that haven t been run in a while like those that have been stored throughout the cooler months and over the winter can sometimes grow quite a bit of bacteria mold and mildew in the condenser coils especially if large buildups of moisture have started to accumulate.
Ge appliance service 1 800 gecares 1 800 432 2737 monday friday.
If the supply cord appears to be undamaged you can remove the cabinet and with.
The fuse will be located near the circuit board.
If power failure occurs turn the air conditioner off.
Your window air conditioner may not turn on because of a blown fuse.
This may cause the unit to cycle off due to compressor overload.
Apply to become an authorized ge appliances.
Check the receptacle with a tester or plug in a known working appliance such as a lamp or a fan to verify that the circuit is live.
Was working fine last night.
The fuse particularly common in newer models helps protect the electronic control.
This turns off the heat pump on models so equipped and will warm the room with electric heat only.
Use the electric heat option.
Check all windows and vents.
Check the air conditioner power supply cord for any signs of fraying or damage.
Check the house fuse circuit breaker box and replace the fuse or reset the breaker.
Once your drain pan drain is clogged and your drain pan itself is full this should trigger your float switch to turn your ac off.
I have a ge window unit that won t come on.
Replace the fuse if it has blown.
It s like it is stuck on delay but it won t let us adjust the delay time.