For example a 4 x 8 loop will give a detection height between 2 1 2 and 2 3 4 feet.
Gate vehicle detector cut in loop installation.
In general direct burial loops are placed below the surface prior to application of asphalt or concrete while cut in loops are installed within a slot sawed into the existing surface.
A 3 16 blade or larger has enough space for sealant to flow.
They are control module components which are installed on the gate operator control or circuit board and operate in tandem with the loop.
Inductance loops are available as direct burial or cut in.
Gate depot provides free technical assistance with all purchases.
For high bed vehicle detection the typical loop size is 6 x 8.
For safety loops the loops should be more that 3 feet from the gate in both the fully open and the fully closed.
Basics of vehicle detection loops.
Loops can be direct burial pave over saw cut cut in or a sensor probe or wand.
Not only great support.
Saw cut loop installation.
Vehicle loops and loop detectors are used to detect the presence of a vehicle to open a gate or as a safety device to prevent the gate from closing on a vehicle in its path.
Choosing the correct size saw blade is important to insure there is enough space for sealant to properly flow when applied.
Hook the loops back up to your detector and see if the gate is still being detected f you try to take advantage of loop phasing and discover that the loops are detecting the gate it may mean that the loops were not properly phased.
We have preformed loops available in both styles as well as loop wire if you.
To install a saw cut loop a groove must be cut.
Normal loops 4 ft x 8 ft are used to detect motorcycles and automobiles.
We carry the most comprehensive selection of.
The minimum distance for the loop to the gate itself is three feet and the.
The height of detection is equal to approximately 2 3 the length of the short side of the loop.
Vehicles exiting the property should trigger the loop with sufficient distance to allow the gate to open.
Don t worry you don t need to pull up the loops and re install them.
A general rule of thumb to follow is that the height of detection is 1 2 to 2 3 the length of the short leg of the loop.
But great prices too.
When sizing your loop a good rule of thumb to follow is.
The attached detector senses this change and triggers a relay output which tells a gate operator that there is a vehicle in the loop.
The height of detection is directly related to the length of the short leg of the loop.